Conduit shall be Anaconda SEALTITE® Type CW. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 1/2" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 1/2" thru 3". Conduit shall be UL listed, CSA certified and IP 67 rated when installed with approved end connectors.
Unidade de medida

Especificações

Tipo

N/A CW

Tamanho comercial elétrica

N/A 1-1/2 in41 mm

Comprimento

N/A 50 ft15.24 m

Embalagens

N/A Embalagem Padrão

Diâmetro Interior

N/A 1.575 to 1.600 in40.005 to 40.640 mm

Diâmetro Externo

N/A 1.865 to 1.900 in47.371 to 48.260 mm

Aprox. Dentro Bend Radius

N/A 5.5 in139.7 mm

Aprox. Peso por 100 ft

N/A 112 lbs50.80 kg

Cor

N/A Azul

Nota

N/A Outras cores estao disponivels para encomenda.
Tamanhos 9,5 mm (3/8 pol.) e 102 mm (4 pol.) estao disponivels por encomenda

Certificações

N/A
UL Listed & CSA Certified

Cross-Reference #

N/A 251024 55-28-11-03 6406-24-00 CB CBLA-15 CBLT-1-1/2 ULBLUE

Core Material

N/A Galvanized Steel

Ingress Protection (IP) Rating

N/A Ingress Protection (IP) 66/67

Jacket Material

N/A Polyvinyl Chloride (PVC)

Jacket Benefits

N/A Liquid Tight Oil Resistant

Instalação

N/A

  • Conduit used with standard liquid-tight connector for easy installation. IP 67 Rated when installed with approved connectors.
  • Approved for both exposed and concealed locations. Rated for temperature ranges -40ºF to + 176ºF (-40ºC to +80ºC).
  • Approved as an equipment grounding conductor in sizes 1/2" through 1-1/4, if the total grounding path is 6 ft. or less and the circuit conductors are protected by over 20 amps for 1/2" and 60 amps or less for 3/4" through 1-1/4".
  • Suitable for use in hazardous locations per NEC Articles 501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article 503 Class III Div. 1 & 2.
  • Manufactured in a full range of trade sizes from 1/2" through 3".
  • Approved for direct burial and in concrete trade sizes 1/2" through 3".
  • Complies with UL Standard 360 File No. E18917; CSA C22.2 File No. 158897; and NEC Article 350.

Artigos de NEC

N/A

  • Artigo 250.118 (6) Aterramento de Equipamentos
  • Artigo 300.22 (D) Equipamentos de Tecnologia da Informacao
  • Artigo 350 Eletroduto Metalico Flexivel Impermeavel (LFMC)
  • Artigo 501.10 (B) (2) Classe I Div. 2
  • Artigo 502.10 (A) (2) e (B) (2)

Aplicativo

N/A Computer Wiring Meets Requirements of NEC
Temperature Range: -40°F to +176°F (-40°C to +80°C)